Technical Support:
158-7527-1139
NDIR technology with independent intellectual property rights
High selectivity for methane gas, no high-concentration poisoning, fast recovery from high-concentration environments
Four-channel detection technology, anti-ethanol/acetic acid interference, avoids false alarms
Ensures high detection accuracy across full temperature and measurement ranges
Long life (>10 years)
Small size, compact structure, easy installation
Tested gas: Methane (CH4)
Operating principle: Non-dispersive infrared detection (NDIR)
Range: 0–100% LEL
Accuracy: 0–25% LEL: ± 3% LEL; 25–50% LEL: ± 5% LEL; 51–100% LEL: ± 10% of reading
Operating temperature: -10 °C–60 °C
Operating humidity: 0–95% RH (non-condensing)
Resolution: 0.1% LEL
Response time: T90 ≤ 30 s
Supply voltage: DC 5–5.5 V
Average operating current: < 100 mA
Ingress protection: IP52